Every tissue region and every cell on an H&E slide, classified
A cell type for every cell and a tissue type for every region. Use the classifiers Orain trained, or train your own on your slides.

Two kinds of classifier, one way of working
Both draw their result on the slide in the same viewer and give the same tables per cell, per region and per slide.
Orain Classifiers
Ready to run. Fixed classes, trained on public expert labels and tested on hospitals they never saw.
- Nothing to label
- The same classes on every slide, so cohorts compare
- Test scores published, weak classes included
Custom Classifiers
Your classes, on your slides. Paint a few examples, and Orain trains a classifier and scores it on tissue it did not train on.
- Any classes you name
- H&E, IHC and multiplex IF
- QuPath annotations in, GeoJSON and a Python model out
You ask for the job. We tell you which classifier does it.
Requests people sent to Orain, and the classifier behind each answer. Ask the same way in chat or from Claude.
“Segment the tissue into tumour epithelium and stroma”
Tissue Classifier →“Detect the nuclei and classify them as tumour cells or lymphocytes”
Cell Classifier →“Find the tumour regions on each slide”
Tissue Classifier →“Count the stromal TILs on every slide of the cohort”
Cell + Tissue Classifier →“Find the B and T cell clusters on my multiplex slides”
Custom Tissue Classifier →“Tell apart the cell types my lab cares about”
Custom Cell Classifier →
From slide to numbers



The Tissue Classifier maps the slide. The Cell Classifier calls every nucleus. Put together, they will give the numbers a study needs, for every slide of a cohort. The numbers above are for the 320 µm field only.
- Tissue area in mm² per class
- Cell counts and densities per mm², per cell class and per tissue class
- Lymphocytes per mm² of stroma and per mm² of tumour
- A per-cell table: position, class, confidence
- The same numbers for every slide of a cohort, in one table
The Orain Classifiers for H&E
Orain H&E Tissue Classifier
Gives each 112 µm tile of the slide one of six tissue classes.

- Tumour
- Stroma
- Immune infiltrate
- Necrosis
- Normal tissue
- Artefact
Orain H&E Cell Classifier
Looks at a 56 µm field around every segmented nucleus and calls its cell type.

- Tumour cell
- Lymphocyte
- Plasma cell
- Fibroblast
- Macrophage
- Other
Open to early research partners now.
How it works
- 01Today
Upload an H&E slide
Any common scanner format. Orain finds the tissue and segments every nucleus.
- 02Today
A foundation model reads it
Hibou-B turns each 112 µm tile into features.
- 03Today
The Cell Classifier calls each nucleus
Cell types are available today; tissue classes per tile come with v1.
- 04With v1
Check it, take the numbers
Review cell-classifier results on the slide and download its table as CSV. Tissue maps come with v1.
The Cell Classifier is available in Orain Studio today. The Tissue Classifier is in development, so tissue maps come with v1. Need other classes? Train a Custom Classifier.
The lineup: every stain, cell and tissue
Each stain gets an Orain Cell Classifier and an Orain Tissue Classifier, with the same classes. Until the Orain one is out, you can train a Custom one.
Tested on tissue it never saw
We keep test slides, and for the cell model whole hospitals, out of training. Weak classes included.
Details
Offline prototype with Tumour, Stroma, Immune infiltrate and Necrosis: 90% of tiles right (88% averaged over the four classes) on breast slides it did not train on (76 TCGA slides, 5,352 expert labels from BCSS). Slides were held out, not yet whole hospitals. Normal tissue and Artefact are being added for v1.
Details
From the slide embedding's own pathology foundation-model pass: the features under each nucleus, made small (48 numbers), a fixed head, and a correction for how common each class is. Sealed test on 4 hospitals it never saw (23,766 labelled cells, NuCLS): 66% of cells right, 48% averaged over the six classes; each class's share of a slide is off by 7 percentage points on average. It finds 76% of tumour cells, 79% of lymphocytes, 61% of fibroblasts and 38% of plasma cells. Macrophages are its weak class: it finds 10% of them, and fewer than 1 in 3 cells it calls a macrophage is one, so a macrophage count is not a measurement. Plasma cells are often called lymphocytes. Both need more pathologist labels.
Training data
TCGA breast slides with the public BCSS and NuCLS expert labels (CC0). The models are trained on breast cancer so far; lung comes next. Pathologist reads on new slides go into each release, and the scores above are updated with them.
Orain Virtual Proteomics
Predicts a 21-marker multiplex immunofluorescence image from an H&E slide: epithelium, T cells, B cells, macrophages, PD-L1, PD-1, Ki67 and more. A prediction for choosing which blocks to stain, never a measurement. We checked it against a real multiplex panel stained on the same section of colorectal cancer, a tissue it never saw.



- Nuclei (DAPI)
- Epithelium (CK)
- T cells (CD3)
- Macrophages (CD68)
Tumour nests in an inflamed stroma: T cells found, the many macrophages missed. In this field (2,847 cells), how well the prediction picks out the cells the stain marks (AUROC, 0.5 is chance): epithelium 0.82, T cells 0.66, macrophages 0.34.
One 0.5 mm field per slide, chosen by a fixed rule: the tumour field with the most T cells by the real stain. Real stain on a log scale, prediction as a probability.Checked against a real 19-marker panel of the same section on 5 colorectal cancer slides it never saw (Orion CRC, 40 fields, 77,823 cells). It finds the cells a real stain marks for epithelium (CK, AUROC 0.81) and T cells (CD3, AUROC 0.77; CD4 0.70), well above nucleus size alone (0.55). CD8, CD20 and Ki67 are weak (0.63-0.66). Macrophages (CD68, 0.38) and PD-L1 (0.47) fail: do not use them. Trained on lung adenocarcinoma; colorectal is out of its domain. On 39 TCGA lung adenocarcinomas, the predictions per slide did not follow the same tumours' RNA (no marker significant); that test compares about 2 mm² of each slide with RNA from another piece of the tumour, so it is weak.
Lung: no agreement found
No open lung dataset has a real multiplex stain on the same section, so we compared the predictions per slide with the same tumours' RNA-seq, on 39 TCGA lung adenocarcinomas. Spearman ρ across 39 slides; no marker passes p < 0.0025 (20 markers tested). About 2 mm² of each slide against RNA from another piece of the tumour: a weak test, not a cell-level check.
Use it for
Biomarker discovery
Tissue and cell features for every slide of a cohort, ready to test against response, survival or mutations.
Case study: anti-HER2 response →Immune contexture
Where the lymphocytes and plasma cells are: inside the tumour, in the stroma, or kept outside.
A Custom Classifier
Need other classes? In Orain Studio you paint examples on your own slides and a Custom Classifier trains on them.
How training works →For research use only. Not for use in diagnostic procedures.
Run the Cell Classifier on your slides
The Orain H&E Cell Classifier is available in Orain Studio. The Tissue Classifier is in development; tell us about your H&E slides and the question you want to answer.
All inquiries are treated as confidential.