Orain · Models for tissue images
Orain Models
Named models for tissue images, with the classes, the data and the numbers stated. One set of tissue and cell classes runs through every stain, so a result on H&E reads the same as one on IHC or multiplex IF. Use the models as they are, compare your samples with analysed cohorts, or train your own from a few annotations.
Classifiers
Two per stain: one maps the tissue, one calls every cell. The classes are the same on every stain.
Tissue classes: Tumour · Stroma · Immune infiltrate · Necrosis · Normal tissue · Artefact
Cell classes: Tumour cell · Lymphocyte · Plasma cell · Fibroblast · Macrophage · Other
Orain H&E Tissue Classifier · v1 · breast
In developmentMaps every part of an H&E slide to the six tissue classes.
Offline prototype with Tumour, Stroma, Immune infiltrate and Necrosis: 90% of tiles right (88% averaged over the four classes) on breast slides it did not train on (76 TCGA slides, 5,352 expert labels from BCSS). Slides were held out, not yet whole hospitals. Normal tissue and Artefact are being added for v1.
Orain H&E Cell Classifier · v1 · breast
AvailableCalls every nucleus on an H&E slide as one of the six cell classes, after the slide's H&E cell analysis; ask for it in chat.
From the slide embedding's own pathology foundation-model pass: the features under each nucleus, made small (48 numbers), a fixed head, and a correction for how common each class is. Sealed test on 4 hospitals it never saw (23,766 labelled cells, NuCLS): 66% of cells right, 48% averaged over the six classes; each class's share of a slide is off by 7 percentage points on average. It finds 76% of tumour cells, 79% of lymphocytes, 61% of fibroblasts and 38% of plasma cells. Macrophages are its weak class: it finds 10% of them, and fewer than 1 in 3 cells it calls a macrophage is one, so a macrophage count is not a measurement. Plasma cells are often called lymphocytes. Both need more pathologist labels.
Orain IHC Cell Classifier · v2 · NSCLC
In developmentCalls every nucleus on a PD-L1 IHC slide as a PD-L1-positive tumour cell, a PD-L1-negative tumour cell or another cell, after the slide's IHC cell analysis, and leaves out detections a pathologist would not count. Research use only: an internal research model trained on non-commercial public data, not for sale.
Trained on IGNITE (PD-L1 IHC of lung cancer, pathologists' cell labels, CC BY-NC-SA 4.0: non-commercial), so research use only and not for sale until it is retrained on labels Orain owns. Reads the foundation-model features under each nucleus, around it and across its tile, its DAB and membrane measurements and its neighbours'. Scored on IGNITE's own end-to-end benchmark (our nucleus detection and its call must both match the pathologist's point within 10 µm; F1 averaged over the three classes) on its 21 held-out patients, 98 regions read by 3 pathologists each, the same 2 centres as training: 0.61 at RUMC and 0.64 at SCDC, against 0.62 and 0.59 for IGNITE's published baseline (YOLOv5) and 0.64 and 0.75 for the pathologists among themselves; v1 scored 0.60 and 0.61. So above the baseline at SCDC and still just below it at RUMC. This was the second time this test set was scored (v1 was the first); every v2 choice was made before, on other patients. Its PD-L1-positive share per region is off the pathologists' by 23 points on average at RUMC (baseline 18, between pathologists 13) and 7 at SCDC (baseline 6, between pathologists 4), and in the same <1%, 1-49% or 50%+ band in 57% of RUMC regions and 83% of SCDC ones. Not a TPS, and untested on other markers, clones, tissues or hospitals.
Orain IHC Tissue Classifier
PlannedThe six tissue classes on IHC slides, so a marker score is counted in the right tissue.
Not trained yet: no public IHC slide set has tissue-class labels (IGNITE's tissue labels are on H&E only). It needs pathologists' tissue labels drawn on IHC slides from at least three hospitals. Today the IHC scores below count positive cells over the regions you draw or the tissue Orain detects.
Orain mIF Cell Classifier
PlannedThe base cell classes plus the subtypes only multiplex panels can see: CD8, CD4, Treg, B cell, macrophage subtypes.
Today: whole-cell segmentation, marker gating and phenotypes on multiplex IF and imaging mass cytometry. On a public IMC lung dataset the phenotypes matched the experts' on 69% of cells.
Orain Spatial Cell Classifier
PlannedCell types for spatial transcriptomics, and RNA-measured truth for the H&E models.
Visium, Xenium, CosMx and MERFISH data open in Orain today.
Scores
One number a pathologist knows, per slide, region or TMA core, with every counted cell drawn on the slide.
Orain Ki67 Score
AvailableKi67 index over the tumour and its hot spot, from every nucleus called negative or 1+/2+/3+.
Mean error 7.1 percentage points, against 9.0 for QuPath's positive cell detection at its defaults (BCData validation set).
Orain ER/PR Score
AvailableH-score and Allred score from the per-nucleus DAB intensities.
Per region or per TMA core; QuPath's column names, and a QuPath-parity run when you want to check a number.
Orain HER2 Score
AvailableHER2 category from membrane staining.
From its own preset, per region or per TMA core.
Orain PD-L1 Score
AvailablePD-L1 tumour proportion score.
From its own preset, per region or per TMA core.
Orain TIL Score
In developmentStromal tumour-infiltrating lymphocytes on H&E, by the international TIL working group method.
Built on the H&E Tissue and Cell Classifiers above; released with them.
Orain H&E Tumour Microenvironment Panel
In developmentPer-slide numbers for studies: cell densities and fractions per tissue class, and the immune phenotype.
Will be checked against RNA (lymphocytes against CD8A expression) and survival in TCGA.
Virtual assays
A stain predicted from the H&E, to choose which blocks are worth the real assay. Never a measurement.
Orain Virtual Proteomics · GigaTIME · research use
AvailablePredicts a 21-marker multiplex immunofluorescence image from an H&E slide: epithelium, T cells, B cells, macrophages, PD-L1, PD-1, Ki67 and more. A prediction for choosing which blocks to stain, never a measurement.
Checked against a real 19-marker panel of the same section on 5 colorectal cancer slides it never saw (Orion CRC, 40 fields, 77,823 cells). It finds the cells a real stain marks for epithelium (CK, AUROC 0.81) and T cells (CD3, AUROC 0.77; CD4 0.70), well above nucleus size alone (0.55). CD8, CD20 and Ki67 are weak (0.63-0.66). Macrophages (CD68, 0.38) and PD-L1 (0.47) fail: do not use them. Trained on lung adenocarcinoma; colorectal is out of its domain. On 39 TCGA lung adenocarcinomas, the predictions per slide did not follow the same tumours' RNA (no marker significant); that test compares about 2 mm² of each slide with RNA from another piece of the tumour, so it is weak.
| Marker | AUROC | Per slide | Size baseline | Verdict |
|---|---|---|---|---|
| CK | 0.81 | 0.73–0.94 | 0.56 | Works |
| CD3 | 0.77 | 0.67–0.83 | 0.55 | Works |
| DAPI | 0.75 | 0.66–0.83 | 0.61 | Works |
| CD4 | 0.70 | 0.65–0.72 | 0.52 | Works |
| Ki67 | 0.66 | 0.42–0.75 | 0.56 | Weak |
| CD20 | 0.66 | 0.52–0.74 | 0.55 | Weak |
| CD8 | 0.63 | 0.50–0.65 | 0.54 | Weak |
| PD-1 | 0.61 | 0.61–0.71 | 0.54 | Weak |
| Actin | 0.53 | 0.45–0.59 | 0.40 | Fails |
| PD-L1 | 0.47 | 0.33–0.51 | 0.54 | Fails |
| CD68 | 0.38 | 0.29–0.56 | 0.49 | Fails |
Lung: No agreement found
TCGA-LUAD: diagnostic H&E slides and the same tumours' RNA-seq (STAR TPM), 39 slides. Spearman ρ across 39 slides; no marker passes p < 0.0025 (20 markers tested). About 2 mm² of each slide against RNA from another piece of the tumour: a weak test, not a cell-level check.
| Marker | RNA | Spearman ρ | p |
|---|---|---|---|
| CK | KRT8, KRT18, KRT19, KRT7 | 0.07 | 0.65 |
| CD3 | CD3E, CD3D, CD3G | 0.08 | 0.65 |
| CD8 | CD8A, CD8B | 0.17 | 0.29 |
| CD20 | MS4A1 | 0.16 | 0.32 |
| CD68 | CD163, CSF1R, C1QA, C1QB | 0.08 | 0.64 |
| PD-L1 | CD274 | 0.27 | 0.10 |
| PD-1 | PDCD1 | 0.23 | 0.17 |
| Ki67 | MKI67 | 0.19 | 0.23 |
| Actin | ACTA2 | -0.39 | 0.02 |
Atlases
Public cohorts Orain has already analysed, ready to compare your samples with: where does your cohort sit, and what is different about it?
NSCLC atlas (TCGA)
AvailableLung adenocarcinoma and squamous cell carcinoma: ADC and bispecific targets, mutations, survival, a patient finder and patient maps. Open to anyone, no login.
1,053 H&E slides; RNA for 994 tumours.
LUAD imaging mass cytometry atlas
AvailableCell-type fractions and survival in lung adenocarcinoma. Ask Orain to compare your IMC samples with it.
416 patients (Sorin et al., 2023).
H&E training atlas
AvailableLabelled H&E slides any workspace can train a classifier on. Its test hospitals are kept out of training, so a model's atlas score is on hospitals it never saw.
300 TCGA slides (150 breast, 150 lung) and 100 more lung patients; 150 breast slides with labelled tissue regions and 110,018 labelled cells. The labels are breast only so far.
Train your own classifier
For the classes your study needs and no catalogue has. No code and no GPU of your own.
- Show it examples. Paint a few regions per class on your slides with the brush in the viewer, or import your QuPath GeoJSON annotations. This works on H&E, IHC and multiplex IF slides once their patch features are computed.
- Orain trains and tells you how good it is. A classifier learns from pathology foundation-model features of your slides and reports its accuracy, per class, on parts of the slide it did not train on, and on whole slides it did not train on when you give it several.
- Correct it. Orain shows you a check set of patches, half picked at random and half where it is least sure; your answers go into the next round.
- Run it on every slide. Each slide gets a map in the viewer and a row of numbers per slide or region, as CSV. Your annotations export to QuPath as GeoJSON, and the model as a bundle with its labels, predictions and a Python predict script.
For a model you will publish or sell: ask Orain to set up a reader study. Several pathologists read the same patches blind in the review panel; Orain reports their agreement (Fleiss' kappa) and sends the disputed patches to an adjudicator.
How training works, with an example on public slides →
Example prompt: “Train a tissue classifier for tumour, stroma and necrosis on these 20 slides. I painted examples on the first 5.”
How we measure
Held-out hospitals
Scores are measured on hospitals the model never saw, not on held-out tiles of slides it trained on.
Pathologist agreement
Pathologists read the same fields; the model is compared with them and with each other.
A molecular check
Where the data allows, a tissue number is checked against RNA from the same tumours.
Research use only
Every Orain model is for research use. None is a diagnostic device.
Questions
Do my slides train the Orain models?
No. Your slides and labels never enter the Orain models or the atlases without your written consent. A classifier you train stays in your workspace.
Which cancers are covered?
The H&E classifiers are trained on breast first, then lung. A released model's name says the cancers it is validated on, for example “· v1 · breast”.
Can I use the models from Claude?
Yes. Add Orain as a connector in Claude and ask in a sentence; the analysis runs in your Orain project and Claude gets the link.
What does it cost?
A free account comes with $5 of credit. Compute, storage and chat charge at provider cost plus 50%; there is no subscription.